In-beam PET measurements of biological half-lives of 12C irradiation induced β+-activity

Authors

  • Fine Fiedler Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, Dresden, Germany
  • Marlen Priegnitz Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, Dresden, Germany
  • Robert Jülich Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, Dresden, Germany
  • Jörg Pawelke Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, Dresden, Germany
  • Paulo Crespo Laboratório de Instrumentação e Física Experimental de Partículas, Departamento de Física, Universidade de Coimbra, Coimbra, Portugal
  • Katia Parodi Heidelberger Ionenstrahl-Therapiezentrum (HIT), Heidelberg, Germany
  • Falk Pönisch Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, Dresden, Germany; Radiation Research in Oncology – Oncoray, Technische Universität Dresden, Dresden, Germany
  • Wolfgang Enghardt Institute of Radiation Physics, Forschungszentrum Dresden-Rossendorf, Dresden, Germany; Radiation Research in Oncology – Oncoray, Technische Universität Dresden, Dresden, Germany

DOI:

https://doi.org/10.1080/02841860701769743

Abstract

One of the long-standing problems in carbon-ion therapy is the monitoring of the treatment, i.e. of the delivered dose to a given tissue volume within the patient. Over the last 8 years, in-beam positron emission tomography (PET) has been used at the experimental carbon ion treatment facility at the Gesellschaft für Schwerionenforschung (GSI) Darmstadt and has become a valuable quality assurance tool.

In order to determine and evaluate the correct delivery of the patient dose, a simulation of the positron emitter distribution has been compared to the measurement. One particular effect is the blurring as well as the reduction of the measured activity distribution via washout.

The objective of this study is the investigation of tissue dependent effective half-lives from patient data. We find no significant dependence of the effective half-life on the Hounsfield unit but on the local dose. The biological half-life within the high dose region is longer than in the low dose region. Furthermore, the influence of the overall treatment time on the kinetics of the positron emitter is reported. There are indications for a metabolic response of the tissue on the irradiation. Taking into account the biological half-life in the simulation leads to an improvement of the quality of the PET-images in some cases.

Downloads

Download data is not yet available.

Downloads

Published

2008-01-01

How to Cite

Fiedler, F. ., Priegnitz, M. ., Jülich, R. ., Pawelke, J. ., Crespo, P. ., Parodi, K. ., … Enghardt, W. . (2008). In-beam PET measurements of biological half-lives of 12C irradiation induced β+-activity. Acta Oncologica, 47(6), 1077–1086. https://doi.org/10.1080/02841860701769743