Volumetric modulated arc therapy versus intensity-modulated proton therapy in the irradiation of infra diaphragmatic Hodgkin Lymphoma in female patients

Authors

  • Johannes Rosenbrock Department of Radiation Oncology, CyberKnife and Radiation Therapy, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
  • Christian Baues Department of Radiation Oncology, CyberKnife and Radiation Therapy, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
  • Andres Vasquez-Torres Department of Radiation Oncology, CyberKnife and Radiation Therapy, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
  • Alessandro Clivio Zentrum für Radiotherapie, Rüti, Switzerland
  • Antonella Fogliata Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy
  • Peter Borchmann Department of Biomedical Sciences, Humanitas University, Milan-Rozzano, Italy; German Hodgkin Study Group, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
  • Christian Baues Department of Radiation Oncology, CyberKnife and Radiation Therapy, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
  • Luca Cozzi Radiotherapy and Radiosurgery Department, Humanitas Research Hospital and Cancer Center, Milan-Rozzano, Italy;e Department of Hematology and Oncology, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany; Department of Biomedical Sciences, Humanitas University, Milan-Rozzano, Italy

DOI:

https://doi.org/10.1080/0284186X.2021.1986230

Keywords:

Intensity-modulated protontherapy, VMAT, RapidArc, lymphoma, secondarycancer risk estimate, ovarian failure

Abstract

Purpose

To investigate the role of infra diaphragmatic intensity-modulated proton therapy (IMPT) compared to volumetric modulated arc therapy (VMAT) for female Hodgkin Lymphoma (HL) patients and to estimate the risk of secondary cancer and ovarian failure.

Methods

A comparative treatment planning study was performed on 14 patients, and the results were compared according to conventional dose-volume metrics. In addition, estimates of the excess absolute risk (EAR) of secondary cancer induction were determined for the bowel, the bladder and the rectum. For the ovaries, the risk of ovarian failure was estimated.

Results

The dosimetric findings demonstrate the equivalence between VMAT and IMPT in terms of target coverage. A statistically significant reduction of the mean and near-to-maximum doses was proven for the organs at risk. The EAR ratio estimated for IMPT to VMAT was 0.51 ± 0.32, 0.32 ± 0.35 and 0.05 ± 0.11 for the bowel, bladder and rectum, respectively. Concerning the risk of ovarian failure for the chronologic age ranging from 18 to 46 years, the expected net loss in fertility years ranged from 4.8 to 3.0 years for protons and 12.0 to 5.7 years for photons.

Conclusion

This in-silico study confirmed the beneficial role of IMPT from a dosimetric point of view. Mathematical models suggested that the use of protons might be further advantageous due to the expected reduction of the risk of secondary cancer induction and its milder impact on the reduction of fertility.

Downloads

Download data is not yet available.

Downloads

Published

2022-01-02

How to Cite

Rosenbrock, J., Baues, C., Vasquez-Torres, A., Clivio, A., Fogliata, A., Borchmann, P., … Cozzi, L. (2022). Volumetric modulated arc therapy versus intensity-modulated proton therapy in the irradiation of infra diaphragmatic Hodgkin Lymphoma in female patients. Acta Oncologica, 61(1), 81–88. https://doi.org/10.1080/0284186X.2021.1986230