Clinical comparative study of dose–volume and equivalent uniform dose based predictions in post radiotherapy acute complications

Authors

  • Thierry P. Boulé Department of Medical Physiology and Biophysics, University of Seville, Seville, Spain
  • M. Isabel Gallardo Fuentes Department of Atomic, Molecular and Nuclear Physics, Faculty of Physics, University of Seville, Seville, Spain
  • Joan V. Roselló Department of Radiotherapy, Valence General University Hospital, Valence, Spain
  • Rafael Arrans Lara Department of Radiophysics, Virgen Macarena University Hospital, Seville, Spain
  • José. L. Torrecilla Department of Radiotherapy, Valence General University Hospital, Valence, Spain
  • Antonio Leal Plaza Department of Medical Physiology and Biophysics, University of Seville, Seville, Spain; Department of Radiophysics, Virgen Macarena University Hospital, Seville, Spain

DOI:

https://doi.org/10.1080/02841860903078513

Abstract

Background. Single points placed on Dose–Volume Histograms (DVHs) for treatment plan acceptance are still widely used compared to the Equivalent Uniform Dose (EUD). The aim of this work is to retrospectively measure and compare the ability of both criteria in correctly predicting two clinical outcomes, RTOG grade 2 acute gastrointestinal (GI) and genitourinary (GU) complications in 137 patients treated for prostate cancer. Material and methods. For both complications, the best predictions have been achieved by fitting the EUD parameter and a tolerance dose (for a varying DVH point) by maximization of the Area Under the Receiver Operating Curve (AUROC). A complementary likelihood fitting of the Lyman's Normal Tissue Complication Probability (NTCP) allowed a graphical comparison between expected and observed frequencies, and to derive the associated parameters. Results and discussion. No significant differences were found in the AUROC values obtained by using dose–volume or EUD criteria, but all the results highlighted the role of high doses. Limiting V65 (for grade 2 GI) or V73 (for grade 2 GU) was as predictive as limiting EUD value, with n equal to 0.09 or 0.06 respectively, but in all cases AUROC values were low (<0.7). Likelihood fitting gave m = 0.195 and TD50 = 72.5 Gy (fixing n = 0.06 for acute GU) and m = 0.19 and TD50 = 66 Gy (fixing n = 0.09 for acute GI). Both AUROC and likelihood values revealed a better fit for acute GI than for acute GU. The use of a fractionation correction, new clinical contours or previous risk factors could improve these values.

Downloads

Download data is not yet available.

Downloads

Published

2009-01-01

How to Cite

Boulé, T. P., Isabel Gallardo Fuentes, M., Roselló, J. V., Arrans Lara, R., Torrecilla, J. L., & Leal Plaza, A. (2009). Clinical comparative study of dose–volume and equivalent uniform dose based predictions in post radiotherapy acute complications. Acta Oncologica, 48(7), 1044–1053. https://doi.org/10.1080/02841860903078513