Assessment of Hypoxia in Experimental Mice Tumours by [ 18 F] Fluoromisonidazole PET and pO 2 Electrode Measurements

Authors

  • Lise Bentzen From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland
  • Susanne Keiding From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland
  • Michael R. Horsman From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland
  • Tove Grönroos From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland
  • Søren B. Hansen From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland
  • Jens Overgaard From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland

DOI:

https://doi.org/10.1080/02841860260088863

Abstract

The aim of this study was to compare a non-invasive 18 F-fluoromisonidazole ([ 18 F]FM ISO) PET assessment of tumour hypoxia with invasive Eppendorf pO 2 measurements in 150-1500 mm 3 C3H mammary carcinomas transplanted on the back of CDF1 mice. The tumour-bearing mice breathed either carbogen gas (95% oxygen, 5% CO 2 ) or normal air during both examinations. Additional autoradiography was performed in separate tumours treated similarly. The PET [18F]FM ISO examination significantly discriminated between tumours of carbogen and air-breathing mice. For the pO 2 measurements, there was a significantly lower percentage of measurements below 2.5 mmHg for carbogen-treated mice compared with air-breathing mice. However, no direct correlation between the methods was seen. A correlation was found between tumour volume and Eppendorf estimates of tumour hypoxia for the animals breathing normal air, but no correlation was found between the PET endpoint and tumour volume. This may be due to low pO 2 measurements obtained in necrotic tissue. Autoradiography confirmed lower [ 18 F]FM ISO uptake in tumours of carbogen-breathing animals compared with air-breathing animals, and demonstrated the heterogeneity of the tracer uptake in small compared with larger tumours.

Downloads

Download data is not yet available.

Author Biography

Lise Bentzen, From the Danish Cancer Society, Department of Experimental Clinical Oncology (L. Bentzen, M.R. Horsman, J. Overgaard), PET Centre (S. Keiding, S.B. Hansen), Department of Medicine V (S. Keiding), Aarhus University Hospital, Aarhus, Denmark and Turku PET Centre (T. Gronroos), Turku, Finland

The aim of this study was to compare a non-invasive 18 F-fluoromisonidazole ([ 18 F]FM ISO) PET assessment of tumour hypoxia with invasive Eppendorf pO 2 measurements in 150-1500 mm 3 C3H mammary carcinomas transplanted on the back of CDF1 mice. The tumour-bearing mice breathed either carbogen gas (95% oxygen, 5% CO 2 ) or normal air during both examinations. Additional autoradiography was performed in separate tumours treated similarly. The PET [18F]FM ISO examination significantly discriminated between tumours of carbogen and air-breathing mice. For the pO 2 measurements, there was a significantly lower percentage of measurements below 2.5 mmHg for carbogen-treated mice compared with air-breathing mice. However, no direct correlation between the methods was seen. A correlation was found between tumour volume and Eppendorf estimates of tumour hypoxia for the animals breathing normal air, but no correlation was found between the PET endpoint and tumour volume. This may be due to low pO 2 measurements obtained in necrotic tissue. Autoradiography confirmed lower [ 18 F]FM ISO uptake in tumours of carbogen-breathing animals compared with air-breathing animals, and demonstrated the heterogeneity of the tracer uptake in small compared with larger tumours.

Downloads

Published

2002-01-01

How to Cite

Bentzen, L., Keiding, S., Horsman, M. R., Grönroos, T., Hansen, S. B., & Overgaard, J. (2002). Assessment of Hypoxia in Experimental Mice Tumours by [ 18 F] Fluoromisonidazole PET and pO 2 Electrode Measurements. Acta Oncologica, 41(3), 304–312. https://doi.org/10.1080/02841860260088863