Effects of Positioning Uncertainty and Breathing on Dose Delivery and Radiation Pneumonitis Prediction in Breast Cancer

Authors

  • Panayiotis Mavroidis From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)
  • Sofie Axelsson From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)
  • Simo Hyödynmaa From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)
  • Juha Rajala From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)
  • Maunu A. Pitkänen From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)
  • Bengt K. Lind From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)
  • Anders Brahme From the Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, Stockholm, Sweden (P. Mavroidis, S. Axelsson, B.K. Lind, A. Brahme) and the Department of Oncology, Tampere University Hospital, Tampere, Finland (S. Hyo dynmaa, J. Rajala, M.A. Pitkanen)

DOI:

https://doi.org/10.1080/028418602320405078

Abstract

The quality of the radiation therapy delivered in the treatment of breast cancer is susceptible to setup errors and organ motion uncertainties. For 60 breast cancer patients (24 resected with negative node involvement, 13 resected with positive node involvement and 23 ablated) who were treated with three different irradiation techniques, these uncertainties are simulated. The delivered dose distributions in the lung were recalculated taking positioning uncertainty and breathing effects into account. In this way the real dose distributions delivered to the patients are more closely determined. The positioning uncertainties in the anteroposterior (AP) and the craniocaudal (CC) directions are approximated by Gaussian distributions based on the fact that setup errors are random. Breathing is assumed to have a linear behavior because of the chest wall movement during expiration and inspiration. 

Downloads

Download data is not yet available.

Downloads

Published

2023-11-17

How to Cite

Mavroidis, P. ., Axelsson, S. ., Hyödynmaa, S. ., Rajala, J. ., Pitkänen, M. A. ., Lind, B. K. ., & Brahme, A. . (2023). Effects of Positioning Uncertainty and Breathing on Dose Delivery and Radiation Pneumonitis Prediction in Breast Cancer. Acta Oncologica, 41(5). https://doi.org/10.1080/028418602320405078