Monitoring of Blood-10B Concentration for Boron Neutron Capture Therapy Using Prompt Gamma-Ray Analysis

Authors

  • Cornelis P.J. Raaijmakers Netherlands Cancer Institute, Antoni van Leeuwenhoek Huis, Amsterdam, The Netherlands
  • Mark W. Konijnenberg Netherlands Cancer Institute, Antoni van Leeuwenhoek Huis, Amsterdam, The Netherlands
  • Luc Dewit Netherlands Cancer Institute, Antoni van Leeuwenhoek Huis, Amsterdam, The Netherlands
  • Dietrich Haritz University Hospital, Hamburg, Germany
  • Rene Huiskamp Netherlands Energy Research Foundation, The Netherlands
  • Katharina Philipp Netherlands Energy Research Foundation, The Netherlands
  • Axel Siefert Commission of the European Communities, Joint Research Centre, Petten, The Netherlands
  • Finn Stecher-Rasmussen Netherlands Energy Research Foundation, The Netherlands
  • Ben J. Mijnheer Netherlands Cancer Institute, Antoni van Leeuwenhoek Huis, Amsterdam, The Netherlands

DOI:

https://doi.org/10.3109/02841869509094017

Abstract

The aim of the present study was to monitor the blood-10B concentration of laboratory dogs receiving boron neutron capture therapy, in order to obtain optimal agreement between prescribed and actual dose. A prompt gamma-ray analysis system was developed for this purpose at the High Flux Reactor in Petten. The technique was compared with inductively coupled plasma-atomic emission spectrometry and showed good agreement. A substantial variation in 10B clearance pattern after administration of borocaptate sodium was found between the different dogs. Consequently, the irradiation commencement was adjusted to the individually determined boron elimination curve. Mean blood-10B concentrations during irradiation of 25.8 ± 2.2 μg/g (1 SD, n = 18) and 49.3 ± 5.3 μg/g (1 SD, n = 17) were obtained for intended concentrations of 25 μg/g and 50 μg/g, respectively. These variations are a factor of two smaller than irradiations performed at a uniform post-infusion irradiation starting time. Such a careful blood-10B monitoring procedure is a prerequisite for accurately obtaining such steep dose-response curves as observed during the dog study.