Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results

Authors

  • Marta Scorsetti IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Mario Bignardi IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Filippo Alongi IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Antonella Fogliata Oncology Institute of Southern Switzerland, Bellinzona, Switzerland
  • Pietro Mancosu IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Simona Castiglioni IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Sara Pentimalli IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Angelo Tozzi IRCCS Istituto Clinico Humanitas, Rozzano (Milano), Italy
  • Luca Cozzi Oncology Institute of Southern Switzerland, Bellinzona, Switzerland

DOI:

https://doi.org/10.3109/0284186X.2011.558522

Abstract

Purpose. To report early clinical experience in stereotactic body radiation therapy (SBRT) delivered using volumetric intensity modulated arc therapy with RapidArc (RA) in patients with primary or metastatic tumours at abdominal sites. Material and methods. Thirty-seven consecutive patients were treated using RA. Of these, 16 had primary or metastatic liver tumours, nine had pancreatic cancer and 12 a nodal metastasis in the retro-peritoneum. Dose prescription varied from 45 to 75 Gy to the Clinical Target Volume in 3 to 6 fractions. The median follow-up was 12 months (6–22). Early local control and toxicity were investigated and reported. Results. Planning objectives on target volumes and organs at risk were met in most cases. Delivery time ranged from 2.8 ± 0.3 to 9.2 ± 2.4 minutes and pre-treatment plan verification resulted in a Gamma Agreement Index from 95.3 ± 3.8 to 98.3 ± 1.7%. At the time of analysis, local control (freedom from progression) at six months, was assessable in 24 of 37 patients and was achieved in 19 patients with a crude rate of 79.2%. Seven patients experienced treatment-related toxicity. Three patients experienced a mild and transient G1 enteritis and two showed a transient G1 liver damage. Two had late toxicity: one developed chronic enteritis causing G1 diarrhoea and G1 abdominal pain and one suffered at three months a G3 gastric bleeding. No patients experienced G4 acute toxicity. Conclusions. SBRT for abdominal targets delivered by means of RA resulted to be feasible with good early clinical results in terms of local control rate and acute toxicity profile. RA allowed to achieve required target coverage as well as to keep within normal tissue dose/volume constraints.

Downloads

Download data is not yet available.

Downloads

Published

2011-05-01

How to Cite

Scorsetti, M., Bignardi, M., Alongi, F., Fogliata, A., Mancosu, P., Castiglioni, S., … Cozzi, L. (2011). Stereotactic body radiation therapy for abdominal targets using volumetric intensity modulated arc therapy with RapidArc: Feasibility and clinical preliminary results. Acta Oncologica, 50(4), 528–538. https://doi.org/10.3109/0284186X.2011.558522