A comprehensive motion analysis – consequences for high precision image-guided radiotherapy of esophageal cancer patients

Authors

  • Catharina T. G. Roos Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Zohra Faiz Department of Surgical Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Sabine Visser Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Margriet Dieters Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Hans Paul van der Laan Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Lydia A. den Otter Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • John T. M. Plukker Department of Surgical Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Johannes A. Langendijk Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Antje-Christin Knopf Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Christina T. Muijs Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
  • Nanna M. Sijtsema Department of Radiation Oncology, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands

DOI:

https://doi.org/10.1080/0284186X.2020.1843707

Keywords:

Esophageal cancer, breathing motion, diaphragm, image guidance, high precision radiotherapy

Abstract

Background and purpose

When treating patients for esophageal cancer (EC) with photon or proton radiotherapy (RT), breathing motion of the target and neighboring organs may result in deviations from the planned dose distribution. The aim of this study was to evaluate the magnitude and dosimetric impact of breathing motion. Results were based on comparing weekly 4D computed tomography (4D CT) scans with the planning CT, using the diaphragm as an anatomical landmark for EC.

Material and methods

A total of 20 EC patients were included in this study. Diaphragm breathing amplitudes and off-sets (changes in position with respect to the planning CT) were determined from delineated left diaphragm structures in weekly 4D CT-scans. The potential dosimetric impact of respiratory motion was shown in several example patients for photon and proton radiotherapy.

Results

Variation in diaphragm amplitudes were relatively small and ranged from 0 to 0.8 cm. However, the measured off-sets were larger, ranging from −2.1 to 1.9 cm. Of the 70 repeat CT-scans, the off-set exceeded the ITV-PTV margin of 0.8 cm during expiration in 4 CT-scans (5.7%) and during inspiration in 13 CT-scans (18.6%). The dosimetric validation revealed under- and overdosages in the VMAT and IMPT plans.

Conclusions

Despite relatively constant breathing amplitudes, the variation in the diaphragm position (off-set), and consequently tumor position, was clinically relevant. These motion effects may result in either treatments that miss the target volume, or dose deviations in the form of highly localized over- or underdosed regions.

Downloads

Download data is not yet available.

Downloads

Additional Files

Published

2021-04-03

How to Cite

Roos, C. T. G., Faiz, Z., Visser, S., Dieters, M., van der Laan, H. P., den Otter, L. A., … Sijtsema, N. M. (2021). A comprehensive motion analysis – consequences for high precision image-guided radiotherapy of esophageal cancer patients. Acta Oncologica, 60(3), 277–284. https://doi.org/10.1080/0284186X.2020.1843707