Feasibility of a wearable soft-robotic glove to support impaired hand function in stroke patients
DOI:
https://doi.org/10.2340/16501977-2357Keywords:
soft-robotic glove, assistive technology, robot-assisted rehabilitation, wearable devices, activities of daily living, upper limb, stroke.Abstract
OBJECTIVE: To investigate the feasibility of a wear-able, soft-robotic glove system developed to combine assistive support in daily life with performing therapeutic exercises on a computer at home (the HandinMind system). DESIGN: Feasibility study. PATIENTS: Five chronic stroke patients with limitations in activities of daily living due to impaired hand function. METHODS: Participants performed a usability test and several functional tasks with the HandinMind system across 2 sessions. Feasibility was measured using the System Usability Scale (SUS), Intrinsic Motivation Inventory (IMI) and performance times of the functional tasks. RESULTS: User acceptance measured by the SUS and IMI was scored high. The median SUS scores of sessions 1 and 2 were 80.0 (interquartile range (IQR) 70.0-88.8) and 77.5 (IQR 75.0-87.5), respectively, and the median IMI score was 6.3 points out of 7 points (IQR 6.2-6.3). Functional task performance was initially slower with the HandinMind glove compared with performance without the glove, but improved up to the level of performance without the glove across no more than 3 repetitions. CONCLUSION: Chronic stroke patients with impaired hand function were positive about the feasibility of the first prototype of the HandinMind system. How-ever, performance and ease of use of the system should be improved further in future development phases.Downloads
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2018 Bob Radder, Gerdienke Prange-Lasonder, Anke Kottink, Alejandro Melendez-Calderon, Jaap Buurke, Hans J.S. Rietman

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
All digitalized JRM contents is available freely online. The Foundation for Rehabilitation Medicine owns the copyright for all material published until volume 40 (2008), as from volume 41 (2009) authors retain copyright to their work and as from volume 49 (2017) the journal has been published Open Access, under CC-BY-NC licences (unless otherwise specified). The CC-BY-NC licenses allow third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work.
From 2024, articles are published under the CC-BY licence. This license permits sharing, adapting, and using the material for any purpose, including commercial use, with the condition of providing full attribution to the original publication.