Responsiveness of the K-Force Grip Dynamometer in patients with ICU-acquired weakness: a prospective longitudinal study
DOI:
https://doi.org/10.2340/jrm.v58.46235Keywords:
ICU-acquired weakness, hand strength, muscle strength dynamometer, critical illness, intensive care unit, rehabilitation, muscle weaknessAbstract
Objective: Handgrip strength is commonly used to assess muscle strength in critically ill patients, including those with intensive care unit-acquired weakness. While the reliability and validity of the K-force grip dynamometer have been established, its responsiveness remains unknown. This study evaluated the responsiveness of handgrip strength measured with the K-force grip dynamometer in intensive care unit-acquired weakness patients.
Methods: In this prospective longitudinal study, intensive care unit-acquired weakness patients were assessed at baseline and after 1 week. Responsiveness was examined using effect sizes and standardized response means. The Medical Research Council sum score was included as a clinical comparator of global measure strength. Changes over time were analysed using Wilcoxon signed-rank tests.
Results: Thirty-six patients were included. Dominant handgrip strength increased from 2650 g to 3450 g, with an effect size of r = 0.86 and standardized response means of 0.77 (p < 0.001). Non-dominant handgrip strength increased from 2,700 g to 3,783 g, with an effect size of r = 0.90 and SRM of 0.70 (p < 0.001). Medical Research Council sum score increased from 26.5 to 30.0 (p < 0.001).
Conclusion: The K-force grip dynamometer demonstrated strong responsiveness in patients with intensive care unit-acquired weakness, supporting its use for detecting short-term changes in handgrip strength in critically ill patients.
Downloads
References
Hiser SL, Casey K, Nydahl P, Hodgson CL, Needham DM. Intensive care unit acquired weakness and physical rehabilitation in the ICU. BMJ 2025; 388: e077292. DOI: https://doi.org/10.1136/bmj-2023-077292
Vanhorebeek I, Latronico N, Van den Berghe G. ICU-acquired weakness. Intensive Care Med 2020; 46: 637–653. DOI: https://doi.org/10.1007/s00134-020-05944-4
Hermans G, Van den Berghe G. Clinical review: intensive care unit acquired weakness. Crit Care 2015; 19: 274. DOI: https://doi.org/10.1186/s13054-015-0993-7
Fiut R, Wasyluk W, Świetlicka I, Szukała MI, Wójcik-Załuska A, Dąbrowski W, et al. Muscle strength in ICU patients measured by handgrip dynamometer and ICU-acquired weakness: a prospective, single-center observational study. Med Sci Monit 2025; 31: e949637. DOI: https://doi.org/10.12659/MSM.949637
van Iperen ID, Stegink D, Tempert-de Haan BL, Flim M, van der Stoep R, Spronk PE. Reliability, validity and usability of the K-force® grip dynamometer to evaluate handgrip-strength in patients with intensive care unit-acquired weakness. Clin Rehabil 2025; 39: 67–77. DOI: https://doi.org/10.1177/02692155241295979
Fess EE, editor. Clinical assessment recommendations. 2nd ed. Mount Laurel NJ: American Society of Hand Therapists; 1992.
Härkönen R, Harju R, Alaranta H. Accuracy of the Jamar dynamometer. J Hand Ther 1993; 6: 259–262. DOI: https://doi.org/10.1016/S0894-1130(12)80326-7
MacDermid J, Solomon G, Valdes K, American Society of Hand Therapists. Clinical assessment recommendations. Impairment-based conditions. 3rd ed. Mount Laurel, NJ: American Society of Hand Therapists; 2015.
Chlan LL, Tracy MF, Guttormson J, Savik K. Peripheral muscle strength and correlates of muscle weakness in patients receiving mechanical ventilation. Am J Crit Care 2015; 24: e91–e98. DOI: https://doi.org/10.4037/ajcc2015277
Wichelhaus A, Harms C, Neumann J, Ziegler S, Kundt G, Prommersberger KJ, et al. Parameters influencing hand grip strength measured with the manugraphy system. BMC Musculoskelet Disord 2018; 19: 54. DOI: https://doi.org/10.1186/s12891-018-1971-4
Gagnier JJ, Lai J, Mokkink LB, Terwee CB. COSMIN reporting guideline for studies on measurement properties of patient-reported outcome measures. Qual Life Res 2021; 30: 2197–2218. DOI: https://doi.org/10.1007/s11136-021-02822-4
Parry SM, Huang M, Needham DM. Evaluating physical functioning in critical care: considerations for clinical practice and research. Crit Care 2017; 21: 249. DOI: https://doi.org/10.1186/s13054-017-1827-6
van der Schaaf M, Sommers J. [Evidence statement for physiotherapy in the intensive care unit]. Houten: Bohn Stafleu van Loghum; 2015 [in Dutch]. DOI: https://doi.org/10.1007/978-90-368-0908-5_4
de Vet HCW, Terwee CB, Mokkink LB, Knol DL. Measurement in medicine: a practical guide. Cambridge: Cambridge University Press; 2011. DOI: https://doi.org/10.1017/CBO9780511996214
Nordon-Craft A, Schenkman M, Edbrooke L, Malone DJ, Moss M, Denehy L. The physical function intensive care test: implementation in survivors of critical illness. Phys Ther 2014; 94: 1499–1507. DOI: https://doi.org/10.2522/ptj.20130451
Stevens RD, Marshall SA, Cornblath DR, Hoke A, Needham DM, de Jonghe B, et al. A framework for diagnosing and classifying intensive care unit-acquired weakness. Crit Care Med 2009; 37: S299–S308. DOI: https://doi.org/10.1097/CCM.0b013e3181b6ef67
Bragança RD, Ataíde TBLS, Mourão LMB, Pinho NCA, Santana MN, Ravetti CG, et al. Intensive care unit acquired weakness, handgrip strength, and mortality in critically ill patients. J Crit Care 2017; 42: 388–393. DOI: https://doi.org/10.1016/j.jcrc.2017.09.056
Hermans G, Clerckx B, Vanhullebusch T, Segers J, Vanpee G, Robbeets C, et al. Interobserver agreement of Medical Research Council sum-score and handgrip strength in the intensive care unit. Muscle Nerve 2012; 45: 18–25. DOI: https://doi.org/10.1002/mus.22219
Parry SM, Berney S, Granger CL, Dunlop DL, Murphy L, El-Ansary D, et al. A new two-tier strength assessment approach to the diagnosis of weakness in intensive care: an observational study. Crit Care 2015; 19: 52. DOI: https://doi.org/10.1186/s13054-015-0780-5
Bragança RD, Ravetti CG, Barreto L, Ataíde TBLS, Carneiro RM, Teixeira AL, et al. Use of handgrip dynamometry for diagnosis and prognosis assessment of intensive care unit acquired weakness: a prospective study. Heart Lung 2019; 48: 532–537. DOI: https://doi.org/10.1016/j.hrtlng.2019.07.001
Bohannon RW. Minimal clinically important difference for grip strength: a systematic review. J Phys Ther Sci 2019; 31: 75–78. DOI: https://doi.org/10.1589/jpts.31.75
Cottereau G, Messika J, Megarbane B, Guérin L, da Silva D, Bornstain C, et al. Handgrip strength to predict extubation outcome: a prospective multicenter trial. Ann Intensive Care 2021; 11: 144. DOI: https://doi.org/10.1186/s13613-021-00932-3
Wu RY, Yeh HJ, Tsai MW, Chen CN. Can handgrip strength reflect muscle dysfunction in individuals in intensive care units? A prospective observational study. Aust Crit Care 2025; 38: 101315. DOI: https://doi.org/10.1016/j.aucc.2025.101315
Downloads
Additional Files
Published
How to Cite
License
Copyright (c) 2026 Ingrid D. van Iperen, Marleen Flim, Peter E. Spronk

This work is licensed under a Creative Commons Attribution 4.0 International License.
All digitalized JRM contents is available freely online. The Foundation for Rehabilitation Medicine owns the copyright for all material published until volume 40 (2008), as from volume 41 (2009) authors retain copyright to their work and as from volume 49 (2017) the journal has been published Open Access, under CC-BY-NC licences (unless otherwise specified). The CC-BY-NC licenses allow third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material for non-commercial purposes, provided proper attribution to the original work.
From 2024, articles are published under the CC-BY licence. This license permits sharing, adapting, and using the material for any purpose, including commercial use, with the condition of providing full attribution to the original publication.