Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation

Authors

  • Jae-Hoon Kim Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
  • Byeong-Hoon Cho Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
  • Jin-Hee Lee Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
  • Soo-Jung Kwon Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea
  • Young-Ah Yi Department of Dentistry, Inje University, Seoul Paik Hospital, Seoul, Republic of Korea
  • Yooseok Shin Microscpoe Center, Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Republic of Korea
  • Byoung-Duck Roh Microscpoe Center, Department of Conservative Dentistry and Oral Science Research Center, College of Dentistry, Yonsei University, Seoul, Republic of Korea
  • Deog-Gyu Seo Department of Conservative Dentistry and Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Republic of Korea

DOI:

https://doi.org/10.3109/00016357.2014.956145

Keywords:

CAD/CAM, internal gap, luting space, marginal gap, micro CT

Abstract

Objective. This study investigated the influence of preparation design on the marginal and internal gap and ceramic thickness of partial ceramic crowns (PCCs) fabricated with the CEREC 3 system. Materials and methods. Sixteen extracted human mandibular molars were prepared according to two different preparation designs (n = 8): a retentive preparation design with traditional cusp capping (Group I) and a non-retentive preparation design with horizontal reduction of cusps (Group II). PCCs were fabricated from IPS Empress CAD with the CEREC 3 system. The parameters for luting space and minimum occlusal ceramic thickness were set to 30 μm and 1.5 mm, respectively. The fabricated PCCs were cemented to their corresponding teeth with self-adhesive resin cement and were then scanned by micro-computed tomography. The marginal and internal gaps were measured at pre-determined measuring points in five bucco-lingual and three mesio-distal cross-sectional images. The ceramic thicknesses of the PCCs were measured at the measuring points for cusp capping areas. Results. Group II (167.4 ± 76.4 μm) had a smaller overall mean gap, which included the marginal and internal gap measurements, than that of Group I (184.8 ± 89.0 μm). The internal gaps were larger than the marginal gaps, regardless of preparation design. Group I presented a thinner ceramic thickness in the cusp capping areas than the minimum occlusal ceramic thickness parameter of 1.5 mm. Conclusion. Preparation design had an influence on fit, particularly the internal gap of the PCCs. Ceramic thickness could be thinner than the minimum ceramic thickness parameter.

Downloads

Download data is not yet available.

Downloads

Published

2015-02-17