Overdenture retaining bar stress distribution: A finite-element analysis

Authors

  • Conrado Reinoldes Caetano Prosthesis and Periodontics
  • Marcelo Ferraz Mesquita Prosthesis and Periodontics
  • Rafael Leonardo Xediek Consani Prosthesis and Periodontics
  • Lourenço Correr-Sobrinho Dental Materials Department, Piracicaba Dental School, State University of Campinas, Piracicaba, SP, Brazil
  • Mateus Bertolini Fernandes Dos Santos Restorative Dentistry Department, School of Dentistry, Federal University of Pelotas, Pelotas, RS, Brazil

DOI:

https://doi.org/10.3109/00016357.2014.923111

Keywords:

finite element analysis, implant inclination, misfit, overdenture

Abstract

Objective. Evaluate the stress distribution on the peri-implant bone tissue and prosthetic components of bar-clip retaining systems for overdentures presenting different implant inclinations, vertical misfit and framework material. Materials and methods. Three-dimensional models of a jaw and an overdenture retained by two implants and a bar-clip attachment were modeled using specific software (SolidWorks 2010). The studied variables were: latero-lateral inclination of one implant (–10°, –5°, 0°, +5°, +10°); vertical misfit on the other implant (50, 100, 200 µm); and framework material (Au type IV, Ag-Pd, Ti cp, Co-Cr). Solid models were imported into mechanical simulation software (ANSYS Workbench 11). All nodes on the bone’s external surface were constrained and a displacement was applied to simulate the settling of the framework on the ill-fitted component. Von Mises stress for the prosthetic components and maximum principal stress to the bone tissue were evaluated. Results. The +10° inclination presented the worst biomechanical behavior, promoting the highest stress values on the bar framework and peri-implant bone tissue. The –5° group presented the lowest stress values on the prosthetic components and the lowest stress value on peri-implant bone tissue was observed in –10°. Increased vertical misfit caused an increase on the stress values in all evaluated structures. Stiffer framework materials caused a considerable stress increase in the framework itself, prosthetic screw of the fitted component and peri-implant bone tissue. Conclusions. Inclination of one implant associated with vertical misfit caused a relevant effect on the stress distribution in bar-clip retained overdentures. Different framework materials promoted increased levels of stress in all the evaluated structures.

Downloads

Download data is not yet available.

Downloads

Published