Influence of the curing mode on the degree of conversion of a dual-cured self-adhesive resin luting cement beneath ceramic

Authors

  • Eduardo José Souza-Junior Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil
  • Boniek Castillo Dutra Borges Department of Dentistry, School of Dentistry, Potiguar University (Laureate International Universities), Natal, Rio Grande do Norte, Brazil
  • Dayane Carvalho Ramos Salles Oliveira Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil
  • William Cunha Brandt Department of Prosthodontics, University of Taubate - UNITAU, Taubaté, São Paulo, Brazil
  • Ronaldo Hirata Department of Restorative Dentistry, ILAPEO, Curitiba, Brazil
  • Emmanuel João Nogueira Leal Silva Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil
  • Mário Alexandre Coelho Sinhoreti Department of Restorative Dentistry, Piracicaba Dental School, State University of Campinas, São Paulo, Brazil

DOI:

https://doi.org/10.3109/00016357.2012.690571

Keywords:

resin cement, conversion degree, ceramic, photocuring

Abstract

Objective. To evaluate the effect of the delayed photoactivation and ceramic barrier on the degree of conversion (DC) of self-adhesive resin cement. Materials and methods. Circular specimens (5 mm in diameter × 1 mm in thickness) of the RelyX U-100 resin cement were made using the following curing protocols (n = 10): (G1) 40 s beneath a IPS Empress II ceramic; (G2) 40 s of direct photocuring; (G3) 80 s beneath the ceramic; (G4) 80 s of direct photocuring; (G5) self-curing; (G6) 5 min in the absence of light (self-curing) followed by transceramic photocuring for 40 s; (G7) 5 min in the absence of light (self-curing) followed by transceramic photocuring for 80 s. All the specimens were photoactivated by LED (800 mW/cm2). After 24 h of dry storage, the DC was measured by FTIR, on the top surface of the specimens. Data were submitted to one-way ANOVA and Tukey test (p ≤ 0.05). Results. Direct photocuring with no ceramic interposition, regardless of the curing time (40 s and 80 s) promoted the highest conversion mean (56.79 ± 1.19 and 59.98 ± 2.93, respectively) and the 5 min delay time for the transceramic photocuring presented a similar mean compared to the immediate transceramic photocuring. The DC was influenced by the ceramic barrier, decreasing the conversion values (49.72 ± 1.91 for 40 s and 52.36 ± 2.50 for 80 s), with no statistical difference from the groups with the previous 5 min of photoactivation delay. The self-cure only showed the worst DC values. Conclusion. Direct photocuring provided a higher degree of conversion for the self-adhesive resin cement. The delayed light activation did not influence the degree of conversion for the resin cement tested.

Downloads

Download data is not yet available.

Downloads

Published

2013-01-01