Efficacy of immediate loading compared to conventional loading in implant-supported removable prostheses: a systematic review and meta-analysis
DOI:
https://doi.org/10.2340/aos.v83.42027Keywords:
Immediate dental implant loading, meta-analysis, dental prosthesis, implant-supported, denture, overlay, partialAbstract
Purpose: This systematic review and meta-analysis aimed to evaluate the efficacy of two different loading methods in implant-supported removable prostheses (partial dentures and full-maxillary dentures).
Methods: As of August 2023, three electronic databases and nine oral implant-related journals had been searched. Only randomised controlled trials (RCTs) that compare immediate loading with conventional loading in implant-supported removable prostheses were included. The primary outcome was the implant survival rate. At the same time, a meta-analysis of bone-level changes was performed. Cochrane risk-of-bias tool for randomised trials (RoB 2) was used to evaluate the risk of bias in the included trials.
Results: A total of 16 RCTs were included, including 543 participants with 1595 implants. The included trials compared immediate loading and conventional loading in implant-supported removable prostheses. Regarding implants as the statistical unit, the immediate loading group had a statistically significant lower survival rate (RR = 0.950; 95% confidence interval [CI], (0.926, 0.974); P = 0.027; I² = 47%). When patients were regarded as statistical units, a statistically significant lower survival rate was also observed in the immediate loading group (RR = 0.929; 95% CI, (0.897, 0.961); P = 0.590; I² = 0%). When we analysed the bone level changes, a statistically significant decrease was observed in bone level in the immediate loading group compared with the conventional loading group (weighted mean difference [WMD] = −0.127; 95% CI, (−0.195, −0.059); P < 0.00001).
Conclusion: Lower implant survival rates and a decrease in marginal bone level was observed compared to immediate loading with conventional loading.
Downloads
References
Buser D, Sennerby L, De Bruyn H. Modern implant dentistry based on osseointegration: 50 years of progress, current trends and open questions. Periodontol 2000. 2017;73(1):7–21. https://doi.org/10.1111/prd.12185 DOI: https://doi.org/10.1111/prd.12185
Pommer B, Danzinger M, Leite Aiquel L, Pitta J, Haas R. Long-term outcomes of maxillary single-tooth implants in relation to timing protocols of implant placement and loading: systematic review and meta-analysis. Clin Oral Implants Res. 2021;32(Suppl 21):56–66. https://doi.org/10.1111/clr.13838 DOI: https://doi.org/10.1111/clr.13838
Oral health-related quality of life of patients rehabilitated with fixed and removable implant-supported dental prostheses [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/35103325/
Prosthetic failures in dental implant therapy [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/35103329/
Comparison of clinical outcomes of immediate versus delayed placement of dental implants: A systematic review and meta-analysis [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/35044012/
Ribeiro AKC, Costa RTF, Vasconcelos BCE, De Moraes SLD, Carreiro AFP, Pellizzer EP. Patient-reported outcome measures and prosthetic events in implant-supported mandibular overdenture patients after immediate versus delayed loading: a systematic review and meta-analysis. J Prosthet Dent. 2024:131(5):833–840. https://doi.org/10.1016/j.prosdent.2022.03.015 DOI: https://doi.org/10.1016/j.prosdent.2022.03.015
Survival rate and peri-implant evaluation of immediately loaded dental implants in individuals with type 2 diabetes mellitus: a systematic review and meta-analysis [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/34586502/
Aldhohrah T, Mashrah MA, Wang Y. Effect of 2-implant mandibular overdenture with different attachments and loading protocols on peri-implant health and prosthetic complications: a systematic review and network meta-analysis. J Prosthet Dent. 2022;127(6):832–844. https://doi.org/10.1016/j.prosdent.2020.12.016 DOI: https://doi.org/10.1016/j.prosdent.2020.12.016
Alsabeeha N, Atieh M, Payne AG. Loading protocols for mandibular implant overdentures: a systematic review with meta-analysis. Clin Implant Dent Relat Res. 2010 May;12 Suppl 1:e28-38. https://doi.org/10.1111/j.1708-8208.2009.00152.x. Epub 2009 Apr 23. PMID: 19438962. DOI: https://doi.org/10.1111/j.1708-8208.2009.00152.x
Schimmel M, Srinivasan M, Herrmann FR, Müller F. Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis. Int J Oral Maxillofac Implants 2014;29(Suppl):271–286. https://doi.org/10.11607/jomi.2014suppl.g4.4 DOI: https://doi.org/10.11607/jomi.2014suppl.g4.4
Ye M, Liu W, Cheng S, Yan L. Immediate vs conventional loading of mandibular overdentures: A comprehensive systematic review and meta-analysis of randomized controlled trials. J. Oral Implantol. 2022;48(1):64–73. https://doi.org/10.1563/aaid-joi-D-20-00265 DOI: https://doi.org/10.1563/aaid-joi-D-20-00265
Page MJ, McKenzie JE, Bossuyt PM, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. BMJ. 2021;372:n71. https://doi.org/10.1136/bmj.n71 DOI: https://doi.org/10.1136/bmj.n71
RoB 2: a revised tool for assessing risk of bias in randomised trials [Internet]. [cited 31-07-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/31462531/
Immediate versus delayed loading of strategic mini-implants under existing removable partial dentures: patient satisfaction in a multi-center randomized clinical trial [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/32533264/
Survival and stability of strategic mini-implants with immediate or delayed loading under removable partial dentures: a 3-year randomized controlled clinical trial [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/36472683/
Schuster AJ, Marcello-Machado RM, Bielemann AM, Possebon APR, Chagas Júnior OL, Faot F. Immediate vs conventional loading of facility-equator system in mandibular overdenture wearers: 1-year RCT with clinical, biological, and functional evaluation. Clin Implant Dent Relat Res. 2020;22(3):270–280. https://doi.org/10.1111/cid.12902. DOI: https://doi.org/10.1111/cid.12902
Komagamine Y, Kanazawa M, Sato D, Minakuchi SA. Preliminary comparison of masticatory performances between immediately loaded and conventionally loaded mandibular two-implant overdentures with magnetic attachments. Clin Implant Dent Relat Res. 2019;21(1):130–137. https://doi.org/10.1111/cid.12698 DOI: https://doi.org/10.1111/cid.12698
Omura Y, Kanazawa M, Sato D, Kasugai S, Minakuchi S. Comparison of patient-reported outcomes between immediately and conventionally loaded mandibular two-implant overdentures: a preliminary study. J Prosthodont Res. 2016;60(3):185–192. https://doi.org/10.1016/j.jpor.2015.12.010 DOI: https://doi.org/10.1016/j.jpor.2015.12.010
Katheng A, Kanazawa M, Komagamine Y, et al. Masticatory performances and maximum occlusal forces of immediate and conventional loaded two-implant supported overdentures retained by magnetic attachments: preliminary study of randomized controlled clinical trial. Int J Implant Dent. 2021;7(1):57. https://doi.org/10.1186/s40729-021-00342-x DOI: https://doi.org/10.1186/s40729-021-00342-x
Stabilizing mandibular complete dentures by a single midline implant-influence on quality of life: 2-year results from a randomized clinical trial comparing different loading protocols [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/31250193/
Mundt T, Passia N, Att W, Pain and discomfort following immediate and delayed loading by overdentures in the single mandibular implant study (SMIS). Clin Oral Investig. 2017;21(2):635–642. https://doi.org/10.1007/s00784-016-1930-0 DOI: https://doi.org/10.1007/s00784-016-1930-0
The single mandibular implant study – Short-term effects of the loading protocol on oral health-related quality of life [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/29402561/
Factors affecting implant stability quotients at immediately and conventionally loaded implants in the posterior Maxilla: a split-mouth randomized controlled trial [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/33215755/
Elsyad MA, Elsaih EA, Khairallah AS. Marginal bone resorption around immediate and delayed loaded implants supporting a locator-retained mandibular overdenture. A 1-year randomised controlled trial. J Oral Rehabil. 2014;41(8):608–618. https://doi.org/10.1111/joor.12182 DOI: https://doi.org/10.1111/joor.12182
Salman A, Thacker S, Rubin S, Dhingra A, Ioannidou E,; Schincaglia GP. Immediate versus delayed loading of mandibular implant-retained overdentures: a 60-month follow-up of a randomized clinical trial. J Clin Periodontol. 2019;46(8):863–871. https://doi.org/10.1111/jcpe.13153 DOI: https://doi.org/10.1111/jcpe.13153
Schincaglia GP, Rubin S, Thacker S, Dhingra A, Trombelli L, Ioannidou E. Marginal bone response around immediate- and delayed-loading implants supporting a locator-retained mandibular overdenture: a randomized controlled study. Int J Oral Maxillofac Implants. 2016;31(2):448–458. https://doi.org/10.11607/jomi.4118 DOI: https://doi.org/10.11607/jomi.4118
Single mandibular implant study – chewing efficiency – 5-year results from a randomized clinical trial using two different implant loading protocols [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/35197416/
Elsyad MA, Al-Mahdy YF, Fouad MM. Marginal bone loss adjacent to conventional and immediate loaded two implants supporting a ball-retained mandibular overdenture: a 3-year randomized clinical trial. Clin Oral Implants Res. 2012;23(4):496–503. https://doi.org/10.1111/j.1600-0501.2011.02173.x DOI: https://doi.org/10.1111/j.1600-0501.2011.02173.x
Immediate and delayed loading of two-piece reduced-diameter implants with locator-analog attachments in edentulous mandibles: one-year results from a randomized clinical trial examining clinical outcome and patient expectation [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/28440024/
Lee K-J, Cha J-K, Sanz-Martin I, Sanz M, Jung U-W. A retrospective case series evaluating the outcome of implants with low primary stability. Clin Oral Implants Res. 2019;30(9):861–871. https://doi.org/10.1111/clr.13491 DOI: https://doi.org/10.1111/clr.13491
Primary stability of implant placement and loading related to dental implant materials and designs: a literature review [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/37799926/
Investigation on primary stability of dental implants through considering peri-implant bone damage, caused by small and large deformations: a validated non-linear micro finite element study [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/37549522/
An in vitro evaluation of primary stability values for two differently designed implants to suit immediate loading in very soft bone [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/33430004/
Hadaya D, Pi-Anfruns J, Bellon B, Pippenger BE, Aghaloo TL. Immediate loading of a fully tapered implant with deep apical threads placed in healed alveolar ridges vs. immediate extraction sockets. Clin Oral Implants Res. 2022; 33(5):501–510. https://doi.org/10.1111/clr.13910 DOI: https://doi.org/10.1111/clr.13910
Flapped versus flapless surgery and delayed versus immediate loading for a four mini implant mandibular overdenture: a RCT on post-surgical symptoms and short-term clinical outcomes [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/35818640/
Stabilizing removable partial dentures by immediate or delayed loading of mini-implants: chewing efficiency in a randomized controlled clinical trial [Internet]. Available from: https://pubmed.ncbi.nlm.nih.gov/31923300/
Eini E, Yousefimanesh H, Ashtiani AH, Saki-Malehi A, Olapour A, Rahim F. Comparing success of immediate versus delay loading of implants in fresh sockets: a systematic review and meta-analysis. Oral Maxillofac Surg. 2022;26(2):185–194. https://doi.org/10.1007/s10006-021-00983-7 DOI: https://doi.org/10.1007/s10006-021-00983-7
Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/33731092/
Zhang H, Ramos V, Bratos M, Liu PP, He W. Effect of the attachments on clinical outcomes of mandibular distal extension implant-supported removable partial dentures: a systematic review. J Prosthet Dent. 2022;128(6):1211–1220. https://doi.org/10.1016/j.prosdent.2021.04.008 DOI: https://doi.org/10.1016/j.prosdent.2021.04.008
Jensen C, Speksnijder CM, Raghoebar GM, Kerdijk W, Meijer HJA, Cune MS. Implant-supported mandibular removable partial dentures: functional, clinical and radiographical parameters in relation to implant position. Clin Implant Dent Relat Res. 2017;19(3):432–439. https://doi.org/10.1111/cid.12484 DOI: https://doi.org/10.1111/cid.12484
Patients experience and satisfaction with immediate loading of implant-supported overdentures – A qualitative study [Internet]. [cited 05-08-2024]. Available from: https://pubmed.ncbi.nlm.nih.gov/37527728/
Trindade Pinto Campos MF, Soares Paiva Tôrres AC, Dantas EM, da Fonte Porto Carreiro A, Barbosa GAS. Masticatory performance and impact on oral health-related quality of life in patients treated with immediately loaded implant-supported prosthesis. Int J Prosthodont. 2021;34(3):300–308. https://doi.org/10.11607/ijp.7017 DOI: https://doi.org/10.11607/ijp.7017
Giannakopoulos NN, Corteville F, Kappel S, Rammelsberg P, Schindler HJ, Eberhard L. Functional adaptation of the masticatory system to implant-supported mandibular overdentures. Clin Oral Implants Res. 2017;28(5):529–534. https://doi.org/10.1111/clr.12830 DOI: https://doi.org/10.1111/clr.12830
Published
Issue
Section
License
Copyright (c) 2024 Zhongke Wang, Sihui Li, Hongmei Chen, Ling Gus

This work is licensed under a Creative Commons Attribution 4.0 International License.
Acta Odontologica Scandinavica publishes original research papers as well as critical reviews relevant to the diagnosis, epidemiology, health service, prevention, aetiology, pathogenesis, pathology, physiology, microbiology, development and treatment of diseases affecting tissues of the oral cavity and associated structures including papers on cause and effect or explanatory/associative relationships for experimental or observational studies.