Decubitus prophylaxis: a prospective trial on the efficiency of alternating-pressure air-mattresses and water-mattresses

Authors

  • KE. Andersen
  • O. Jensen
  • SA. Kvorning
  • E. Bach

DOI:

https://doi.org/10.2340/0001555563227230

Abstract

Six hundred patients at risk for pressure sores were randomized in either a control group or one of two experimental groups placed on alternating-pressure air-mattresses and water-mattresses. The groups remained comparable throughout the 10-day study period. Twenty-one patients from the control group developed decubitus ulcers, compared with 7 in each of the other groups. Patient and ward personnel opinions on the acceptability of the three types of mattresses were registered.

Downloads

Download data is not yet available.

Downloads

Published

1983-05-01

How to Cite

Andersen, K., Jensen, O., Kvorning, S., & Bach, E. (1983). Decubitus prophylaxis: a prospective trial on the efficiency of alternating-pressure air-mattresses and water-mattresses. Acta Dermato-Venereologica, 63(3), 227–230. https://doi.org/10.2340/0001555563227230

Issue

Section

Articles