Dimensional stability of two impression materials after a 6-month storage period

Authors

  • Francisco Martins Oral Rehabilitation Department, Instituto Superior de Ciências da Saúde Egas Moniz, Almada, Portugal
  • Patrícia Branco Oral Rehabilitation Department, Instituto Superior de Ciências da Saúde Egas Moniz, Almada, Portugal
  • José Reis Oral Rehabilitation Department, Instituto Superior de Ciências da Saúde Egas Moniz, Almada, Portugal
  • Ignacio Barbero Navarro Oral Medicine Department, Facultad de Odontología, Universidad de Sevilla, Sevilla, Spain
  • Paulo Maurício Oral Rehabilitation Department, Instituto Superior de Ciências da Saúde Egas Moniz, Almada, Portugal

DOI:

https://doi.org/10.1080/23337931.2017.1401933

Keywords:

Elastomers, sterilization, laser interferometry

Abstract

Objective: Oral rehabilitation success is enhanced by an accurate and reproducible final impression. The purpose of this study is to evaluate the dimensional changes of a polyether and addition silicone subjected to disinfection and/or sterilization after a long storage period.

Material and methods: Ninety samples were obtained from polyether ImpregumTM PentaTM (3M ESPETM, Seefeld, Germany) and 90 of addition silicone ImprintTM 4 PentaTM Putty (3M ESPETM, Seefeld, Germany) according to ISO 4823:2000. The samples of each material were split to form three groups with 30 samples each: a control group, a hypochlorite group (disinfection) and an autoclave group (sterilization). Samples were stored in the Portuguese Institute for Quality for six months at 23 °C. Samples were measured by laser interferometry, according to the Michelson technique before calculating dimensional stability according ISO 4823:2000. A statistical analysis via a three-way mixed ANOVA was performed.

Results: Significant shrinkage of ImpregumTM PentaTM was 0.77 ± 0.17% in the control group, 0.42 ± 0.19% in the hypochlorite group and 0.52 ± 0.28% in the autoclave group. For ImprintTM 4 PentaTM Putty, the control group had a shrinkage of 0.42 ± 0.12%, the hypochlorite group 0.36 ± 0.09% and the autoclave group 0.59 ± 0.13%.

Conclusions: The long-term storage of samples subjected to disinfection with 5.25% hypochlorite or autoclave sterilization can be used in a clinical setting as the dimensional changes are below the maximum permitted by the ISO 4823:2000, since there are no clinically significant changes in the dimension of the samples during the storage period.

Downloads

Download data is not yet available.

Downloads

Published

2017-01-01

How to Cite

Martins, F., Branco, P., Reis, J., Barbero Navarro, I., & Maurício, P. (2017). Dimensional stability of two impression materials after a 6-month storage period. Biomaterial Investigations in Dentistry, 3(1), 84–91. https://doi.org/10.1080/23337931.2017.1401933