Marginal and internal fit of crowns based on additive or subtractive manufacturing

Authors

  • Yasser Haddadi Department of Dentistry and Oral Health, Section for Prosthodontics, Aarhus University, Aarhus, Denmark
  • Bahram Ranjkesh Department of Dentistry and Oral Health, Section for Prosthodontics, Aarhus University, Aarhus, Denmark
  • Flemming Isidor Department of Dentistry and Oral Health, Section for Prosthodontics, Aarhus University, Aarhus, Denmark
  • Golnosh Bahrami Department of Dentistry and Oral Health, Section for Prosthodontics, Aarhus University, Aarhus, Denmark

DOI:

https://doi.org/10.1080/26415275.2021.1938576

Keywords:

Additive manufacturing, 3D printing, digital dentistry, marginal fit, internal fit, fit of crowns

Abstract

Objective

To assess the marginal and internal fit of crowns manufactured by additive and subtractive manufacturing technique.

Materials and Methods

Twenty extracted teeth prepared for complete coverage crowns were scanned with an intra-oral scanner (Omnicam, DentsplySirona). For the subtractive manufacturing (SM) group, ten crowns were manufactured in a hybrid resin block (Vita Enamic, Vita Zahnfabrik). For the additive manufacturing (AM) group, the crowns were manufactured in a hybrid resin material (NextDent C&B, 3D systems). The design parameters were identical for the two groups. The marginal and internal fit (determined at the axial wall, the cusp tip and occlusally) was assessed before cementation with the replica technique and after cementation under stereomicroscope after sectioning of the crowned teeth.

Results

For the SM group, the marginal fit was 91 µm (±28 µm) before cementation and 85 µm (±18 µm) after cementation. In the AM group, the marginal fit was 75 µm (±29 µm) before cementation and 71 µm (±18 µm) after cementation. The differences were not statistically significant. As regards the internal fit, the fit at the axial wall was statistically significantly better in the SM group than in the AM group (p=.009 before cementation and .03 after cementation). Occlusally the fit in the AM group was significantly better than in the SM group after cementation (p<.001).

Conclusion

Within the limitations of the current study, the marginal fit of additively manufactured crowns is comparable to crowns manufactured with chair-side subtractive technique and within the clinically acceptable range. As regards the internal fit no one technique was consistently superior.