Physical-chemical characterization and bond strength to zirconia of dental adhesives with different monomer mixtures and photoinitiator systems light-activated with poly and monowave devices

Authors

  • Constantino Fernandes Neto a Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
  • Mayara Hana Narimatsu a Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
  • Pedro Henrique Magão a Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
  • Reginaldo Mendonça da Costa a Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil
  • Carmem Silvia Pfeifer b Division of Biomaterials and Biomechanics, Department of Restorative Dentistry, School of Dentistry, Oregon Health and Science University, Portland, OR, USA
  • Adilson Yoshio Furuse a Department of Operative Dentistry, Endodontics and Dental Materials, Bauru School of Dentistry, University of São Paulo, Bauru, Brazil

DOI:

https://doi.org/10.1080/26415275.2022.2064289

Keywords:

Adhesives, ceramics, zirconia, bond strength

Abstract

Abstract

Introduction: Bonding to crystalline zirconia is currently a challenge. Properly cured adhesives are crucial to optimize this bond, and that in turn is influenced by the initial mobility of the system, as well as by the reactivity of the initiators. Aim: This study aimed to characterize adhesives containing monomer mixtures of different viscosities and double and triple photoinitiator systems; and to evaluate the bonding to Y-TZP zirconia, when adhesives were light-activated with monowave or polywave light-curing units (LCU). Materials and methods: Adhesives were formulated at a 1:1 weight proportion of Bis-GMA/TEGDMA or Bis-GMA/Bis-EMA. To these mixtures 0.5 wt% of CQ, 0.5–1.0 wt% of DABE, 0.5–1.0 wt% of DPIHP, or 0.5–1.0 wt% of TAS-Sb were added and used as photoinitiator systems. A total of ten adhesives were prepared. Resin composite cylinders were cemented on zirconia slices and 6000 thermal cycles were performed. Degree of conversion (DC), sorption (SO) and solubility (SL) after 7 days of water storage, and microshear bond strength (µSBS) were evaluated. Data were analyzed with three-way ANOVA and Tukey’s HSD (α = 0.05). Results: Bis-GMA/Bis-EMA combined with either CQ/DABE or CQ/DABE/TAS-Sb presented the highest DC, and no significant differences were observed for LCUs (p = .298). CQ/DABE < CQ/DABE/TAS-Sb ≈ CQ/DABE/DPIHP and the polywave LCU showed smaller overall SO (p < .05). Bis-GMA/TEGDMA with CQ/DABE cured with the polywave LCU presented the lowest SO. SL varied as follows: CQ/DABE/TAS-Sb < CQ/DABE/DPIHP < CQ/DABE (p < .001). For µSBS, only the factor photoinitiator system was significant (p = .045). All mean values were above 30 MPa, with higher values being observed for BIS-GMA/TEGDMA and CQ/DABE. Conclusion: It can be concluded that the adhesive containing CQ/DABE/TAS-Sb as coinitiator of Bis-GMA/Bis-EMA mixtures produced a material with higher DC and lower SL, while bond strength values were similar to the ones obtained by CQ/DABE.

Downloads

Download data is not yet available.

Downloads

Published

2022-12-31

How to Cite

Fernandes Neto, C., Hana Narimatsu, M., Henrique Magão, P., Mendonça da Costa, R., Silvia Pfeifer, C., & Yoshio Furuse, A. (2022). Physical-chemical characterization and bond strength to zirconia of dental adhesives with different monomer mixtures and photoinitiator systems light-activated with poly and monowave devices. Biomaterial Investigations in Dentistry, 9(1), 20–32. https://doi.org/10.1080/26415275.2022.2064289