An in vitro assessment of biaxial flexural strength, degree of monomer conversion, color stability, and ion release in provisional restorations containing Sr-bioactive glass nanoparticles

Authors

  • Chawal Padunglappisit Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand
  • Napassorn Suwanprateep Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand
  • Harit Chaiwerawattana Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand
  • Parichart Naruphontjirakul Biological Engineering Program, Faculty of Engineering, King Mongkut’s University of Technology Thonburi, Bangkok, Thailand
  • Piyaphong Panpisut Faculty of Dentistry, Thammasat University, Pathum Thani, Thailand;  Thammasat University Research Unit in Dental and Bone Substitute Biomaterials, Thammasat University, Pathum Thani, Thailand

DOI:

https://doi.org/10.1080/26415275.2023.2265393

Keywords:

Provisional restoration, degree of monomer conversion, bioactive glass, biaxial flexural strength, color stability, ion release

Abstract

This study examined the mechanical and chemical properties of an experimental provisional restoration containing Sr-bioactive glass nanoparticles (Sr-BGNPs) compared to commercial provisional materials. The experimental material (TempS10) contained dimethacrylate monomers with added 10 wt% Sr-BGNPs. The degree of monomer conversion (DC) of self-curing (n = 5), biaxial flexural strength (BFS)/modulus (BFM) (n = 5), and color changes (ΔE*00) of materials in red wine (n = 5) were determined. Additionally, ion release (Ca, P, and Sr) in water at 2 weeks was examined (n = 3). The commercial materials tested included polymethyl methacrylate-based provisional material (Unifast) and bis-acrylic materials (Protemp4 and Cooltemp). TempS10 exhibited a comparable degree of monomer conversion (49%) to that of Protemp4 (60%) and Cooltemp (54%) (p > 0.05). The DC of Unifast (81%) was significantly higher than that of other materials (p < 0.05). TempS10 showed a BFS (126 MPa) similar to Cooltemp (102 MPa) and Unifast (123 MPa), but lower than Protemp4 (194 MPa). The immersion time for 2 weeks exhibited no detrimental effect on the strength and modulus of all materials. The highest ΔE*00 at 24 h and 2 weeks was observed with TempS10, followed by Cooltemp, Unifast, and Protemp4. Only TempS10 showed a detectable amount of Ca (0.69 ppm), P (0.12 ppm), and Sr (3.01 ppm). The experimental provisional resin restoration containing Sr-BGNPs demonstrated polymerization and strength comparable to those of bis-acryl provisional restorations but with the added benefit of ion-releasing properties. However, the experimental material demonstrated unsatisfactory color stability.

Downloads

Download data is not yet available.

Downloads

Published

2023-12-31

How to Cite

Padunglappisit, C., Suwanprateep, N., Chaiwerawattana, H., Naruphontjirakul, P., & Panpisut, P. (2023). An in vitro assessment of biaxial flexural strength, degree of monomer conversion, color stability, and ion release in provisional restorations containing Sr-bioactive glass nanoparticles. Biomaterial Investigations in Dentistry, 10(1). https://doi.org/10.1080/26415275.2023.2265393