Corrosion resistance of straight and C-clasp stainless steel wrought wires in artificial saliva

Authors

  • Eri Hendra Jubhari Department of Prosthodontics, Faculty of Dentistry, Hasanuddin University, Makassar, Indonesia; Hasanuddin University Dental Hospital, Makassar, Indonesia
  • Baiq Zalfa Zahira Aurellia Nityasari Hasanuddin University Dental Hospital, Makassar, Indonesia; Faculty of Dentistry, Hasanuddin University, Makassar, Indonesia
  • Rifaat Nurrahma Department of Prosthodontics, Faculty of Dentistry, Hasanuddin University, Makassar, Indonesia; Hasanuddin University Dental Hospital, Makassar, Indonesia

DOI:

https://doi.org/10.2340/biid.v13.46369

Keywords:

stainless steel, corrosion, saliva pH, wire bending, removable partial denture

Abstract

Background: Stainless steel wires are commonly used in removable partial dentures, but their corrosion resistance may be affected by intraoral pH changes and mechanical deformation, such as bending into C-clasps.

Objective: To evaluate the corrosion resistance of straight and C-clasp stainless steel wires in artificial saliva (pH 5.5 and 7.0) and to assess the influence of bending on corrosion behavior.

Materials and methods: An in vitro experimental study was conducted using four groups of stainless steel wires: straight pH 5.5, C-clasp pH 5.5, straight pH 7.0, and C-clasp pH 7.0. The samples were immersed for 4 weeks, with weekly weight measurements and corrosion rate calculations performed. Data were analyzed using repeated measures analysis of variance (ANOVA) or the Friedman test and two-way ANOVA for intergroup comparisons.

Results: Two-way ANOVA revealed a significant effect of pH on corrosion behavior (p < 0.001), whereas wire configuration had no significant effect (p > 0.05). Acidic conditions (pH 5.5) resulted in significantly greater weight loss in both straight and C-clasp wires than neutral conditions, indicating increased corrosion in acidic environments. At pH 7.0, the corrosion rates were minimal or slightly negative, suggesting limited corrosion or minor weight changes.

Conclusion: Environmental pH plays a central role in corrosion behavior, with acidic conditions accelerating degradation. No significant effect of bending into a C-clasp on corrosion susceptibility was observed under the present conditions. Maintaining an optimal oral pH may help preserve the integrity of stainless steel components in removable partial dentures.

Downloads

Download data is not yet available.

References

Rahmayani L, Novita CF, Ahya W. Emotional impact survey of dental patients with tooth loss in Unsyiah Dental Hospital, Banda Aceh, ndonesia. World J Dent. 2018;9(1):24–8. DOI: https://doi.org/10.5005/jp-journals-10015-1501

Dewi RS, Ardinda TK, Koesmaningati H. Confidence of clinical year dental students in performing removable denture treatment and their perception of the quality of prosthodontic studies. J Dentomaxillofac Sci. 2023;8(3):188–92. DOI: https://doi.org/10.15562/jdmfs.v8i3.1535

Şakar O, editor. Removable partial dentures. Cham: Springer; 2016. p. 101–102. DOI: https://doi.org/10.1007/978-3-319-20556-4

Carr AB, Brown David T. McCracken’s removable partial prosthodontics. 13th ed. St. Louis, MO: Elsevier; 2016.

Fibryanto E, Sutanto AVR. Effect of brushing the teeth after meals on salivary pH of elderly people with removable dentures: a quasi experimental study. World J Dent. 2024;14(12):1027–31. DOI: https://doi.org/10.5005/jp-journals-10015-2340

Vaicelyte A, Janssen C, Le Borgne M, Grosgogeat B. Cobalt–chromium dental alloys: metal exposures, toxicological risks, CMR classification, and EU regulatory framework. Crystals (Basel). 2020;10(12):1151. DOI: https://doi.org/10.3390/cryst10121151

slam N. Corrosion and its effect: a critical appraisal. J Surv Fish Sci. 2022;9(1):396–408.

Łosiewicz B, Osak P, Górka-Kulikowska K, Goryczka T, Dworak M, Maszybrocka J, et al. Effect of artificial saliva modification on pitting corrosion and mechanical properties of the Remanium®-type orthodontic archwire. Materials. 2023;16(20):1–24. DOI: https://doi.org/10.3390/ma16206791

Haugli KH, Syverud M, Samuelsen JT. Ion release from three different dental alloys – effect of dynamic loading and toxicity of released elements. Biomater Investig Dent. 2020;7(1):71–9. DOI: https://doi.org/10.1080/26415275.2020.1747471

Holm C, Morisbak E, Kalfoss T, Dahl JE. In vitro element release and biological aspects of base–metal alloys for metal-ceramic applications. Acta Biomater Odontol Scand. 2015;1(2–4):70–5. DOI: https://doi.org/10.3109/23337931.2015.1069714

Wang Z, Seyeux A, Zanna S, Maurice V, Marcus P. Chloride-induced alterations of the passive film on 316L stainless steel and blocking effect of pre-passivation. Electrochim Acta. 2020;329:135159. DOI: https://doi.org/10.1016/j.electacta.2019.135159

Tanhaei S, Gheisari K, Alavi Zaree SR. Effect of cold rolling on the microstructural, magnetic, mechanical, and corrosion properties of AISI 316L austenitic stainless steel. Int J Miner Metall Mater. 2018;25(6):630–40. DOI: https://doi.org/10.1007/s12613-018-1610-y

Ma C, Du Z, Wang X, Zhou P, Zhao Y, Hua Y, et al. Corrosion of stainless steels and corrosion protection strategies in the semiconductor manufacturing industry: a review. Corros Rev. 2024;42(2):127–61. DOI: https://doi.org/10.1515/corrrev-2023-0051

Wang Z, Di-Franco F, Seyeux A, Zanna S, Maurice V, Marcus P. Passivation-induced physicochemical alterations of the native surface oxide film on 316L austenitic stainless steel. J Electrochem Soc. 2019;166(11):C3376–88. DOI: https://doi.org/10.1149/2.0321911jes

to A, Kitaura H, Noguchi T, Ohori F, Mizoguchi I. Analysis of coating loss from coated stainless steel orthodontic wire. Appl Sci. 2022;12(19):9497. DOI: https://doi.org/10.3390/app12199497

Bhat VS, Nandish B, Jayaprakash K. Science of dental materials with clinical applications. 3rd ed. New Delhi: CBS Publishers & Distributors; 2019.

Eduok U, Szpunar J. In vitro corrosion studies of stainless-steel dental substrates during Porphyromonas gingivalis biofilm growth in artificial saliva solutions: providing insights into the role of resident oral bacterium. RSC Adv. 2020;10(52):31280–94. DOI: https://doi.org/10.1039/D0RA05500J

Shaheed A, Nori SA, Salman LH, Said AM. Effect of prosthodontic and orthodontic appliances on salivary pH: prospective study. Syst Rev Pharm. 2020;11(11):1013–15.

Močnik P, Kosec T, Kovač J, Bizjak M. The effect of pH, fluoride and tribocorrosion on the surface properties of dental archwires. Mater Sci Eng. 2017;78:682–9. DOI: https://doi.org/10.1016/j.msec.2017.04.050

Tomova Z, Tomov D, Davcheva D, Uzunova Y. Salivary chromium and cobalt concentrations in patients with dental metallic restorations – a pilot study. Dent J (Basel). 2024;12(11):362. DOI: https://doi.org/10.3390/dj12110362

Al saqer MAS, Al-Waeli WAAR. The effect of mouthwashes on the corrosion resistance of stainless steel wire. Iraqi Dent J. 2017;39(2):59. DOI: https://doi.org/10.26477/idj.v39i2.124

Hobbelink MG, He Y, Xu J, Xie H, Stoll R, Ye Q. Synergistic effect of wire bending and salivary pH on surface properties and mechanical properties of orthodontic stainless steel archwires. Prog Orthod. 2015;16(1):37. DOI: https://doi.org/10.1186/s40510-015-0109-6

Behvar A, Aghayar Y, Avateffazeli M, Tridello A, Benelli A, Paolino DS, et al. Synergistic impact of corrosion pitting on the rotating bending fatigue of additively manufactured 316L stainless steel: integrated experimental and modeling analyses. Int J Fatigue. 2024;188:108491. DOI: https://doi.org/10.1016/j.ijfatigue.2024.108491

Dula LJ, Ahmedi EF, Lila-Krasniqi ZD, Shala KS. Clinical evaluation of removable partial dentures on the periodontal health of abutment teeth: a retrospective study. Open Dent J. 2015;9(1):132–9. DOI: https://doi.org/10.2174/1874210601509010132

Fróis A, Santos AC, Louro CS. Corrosion of fixed orthodontic appliances: causes, concerns, and mitigation strategies. Metals (Basel). 2023;13(12):1955. DOI: https://doi.org/10.3390/met13121955

Published

2026-07-02

How to Cite

Jubhari, E. H., Aurellia Nityasari, B. Z. Z., & Nurrahma, R. (2026). Corrosion resistance of straight and C-clasp stainless steel wrought wires in artificial saliva. Biomaterial Investigations in Dentistry, 13(1), 564–570. https://doi.org/10.2340/biid.v13.46369