Fracture strength of CAD/CAM glass fiber post-and-cores: a systematic review

Authors

  • Amira Yousfi Department of Prosthodontics, Faculty of Dental Medicine, University of Monastir, Monastir, Tunisia
  • Rihab Dakhli Department of Prosthodontics, Faculty of Dental Medicine, University of Monastir, Monastir, Tunisia

DOI:

https://doi.org/10.2340/biid.v13.46724

Keywords:

CAD/CAM, glass fiber post-and-core, fracture strength, endodontically treated teeth, fiber-reinforced composite, post-and-core

Abstract

Background/Objective(s)/Introduction: Endodontically treated teeth with extensive coronal tissue loss often require post-and-core restorations to provide retention and support for definitive restorations. Recent advances in computer-aided design/computer-aided manufacturing (CAD/CAM) technology have enabled the fabrication of customized glass fiber post-and-core systems with improved adaptation to root canal anatomy. However, evidence regarding their fracture strength remains inconsistent. This systematic review aimed to evaluate the fracture strength of CAD/CAM-fabricated glass fiber post-and-core systems, compare their performance with that of other post systems, and identify the factors influencing their fracture strength.

Materials and Methods: A systematic review was conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251038278). Electronic searches were performed in PubMed, Scopus, Web of Science, and Cochrane Library in January 2025 and updated in February 2026. Studies evaluating the fracture strength of CAD/CAM glass fiber post-and-core systems were included. Data regarding study characteristics, materials, testing methods, aging procedures, fracture strength outcomes, failure modes, and principal findings were extracted. Methodological quality was assessed using a modified CONSORT checklist adapted for in vitro studies.

Results: A total of 17 studies met the eligibility criteria. Fracture strength values varied considerably according to material composition, testing protocols, and experimental conditions. CAD/CAM glass fiber post-and core systems generally demonstrated fracture strength comparable to cast metal and other contemporary post systems. Improved adaptation to root canal anatomy and thinner cement layers were consistently reported. Although some materials exhibited higher fracture strength values, CAD/CAM glass fiber posts were frequently associated with more favorable and repairable failure modes.

Conclusion(s): CAD/CAM-fabricated glass fiber post-and-core systems represent a promising alternative to conventional post systems, providing fracture strength comparable to established restorative options while promoting more favorable failure behavior. However, methodological heterogeneity among studies highlights the need for standardized testing protocols and further clinical investigations.

Downloads

Download data is not yet available.

References

Ignatious V, Thilak Shetty B, Saldanha S, Rodrigues S, Mahesh M, Pai U, et al. Comparison and evaluation of fracture resistance of endodontically treated maxillary central incisors with 3 different bonded post and cores: an in vitro study. Indian J Forensic Med Toxicol. 2019;13(4):270–5. DOI: https://doi.org/10.5958/0973-9130.2019.00302.5

Falcão Spina DR, Goulart da Costa R, Farias IC, da Cunha LG, Ritter AV, Gonzaga CC, et al. CAD/CAM post-and-core using different esthetic materials: fracture resistance and bond strengths. Am J Dent. 2017;30(6):299–304.

Krommydas K, Niakou A, Stratos A, Kamalakidis SN, Pissiotis A, Michalakis K, et al. Biomechanical behavior of various post-and-core systems in severely compromised mandibular molars: a 3D finite element analysis. J Prosthet Dent. 2026. DOI: https://doi.org/10.1016/j.prosdent.2026.06.031

Bilgin MS, Erdem A, Dilber E, Ersoy İ. Comparison of fracture resistance between cast, CAD/CAM milling, and direct metal laser sintering metal post systems. J Prosthodont Res. 2016;60(1):23–8. DOI: https://doi.org/10.1016/j.jpor.2015.08.001

Pang J, Feng C, Zhu X, Liu B, Deng T, Gao Y, et al. Fracture behaviors of maxillary central incisors with flared root canals restored with CAD/CAM integrated glass fiber post-and-core. Dent Mater J. 2019;38(1):114–9. DOI: https://doi.org/10.4012/dmj.2017-394

Rakotoaridina K, Delrieu J, Pages P, Vergé T, Nasr K, Canceill T. Evaluation of poly(etheretherketone) post’s mechanical strength in comparison with three metal-free biomaterials: an in vitro study. Polymers. 2023;15(17):3583. DOI: https://doi.org/10.3390/polym15173583

Eid R, Juloski J, Ounsi H, Silwaidi M, Ferrari M, Salameh Z. Fracture resistance and failure pattern of endodontically treated teeth restored with computer-aided design/ computer-aided manufacturing post and cores: a pilot study. J Contemp Dent Pract. 2019;20(1):56–63. DOI: https://doi.org/10.5005/jp-journals-10024-2476

Ntovas P, Sailer I, Fehmer V, Revilla-León M. Restoration of endodontically treated teeth using a CAD-CAM custom post-and-core system: a direct-indirect digital workflow for post space acquisition. J Prosthet Dent. 2026;S0022-3913(26)00401-4. DOI: https://doi.org/10.1016/j.prosdent.2026.05.049

Albuquerque R de C, Nakagawa RK, Maia LM, da Silveira RR, Alves NRF. Precision and predictability in tooth rehabilitation using a chairside digital workflow: A 6-year follow-up. J Prosthet Dent. 2026;2026(2):335-338. DOI: https://doi.org/10.1016/j.prosdent.2026.03.038

Eid R, Tribst JPM, Juloski J, Özcan M, Salameh Z. Effect of material types on the fracture resistance of maxillary central incisors restored with CAD/CAM post and cores. Int J Comput Dent. 2021;24(1):41–51.

de Melo-Soares V, Yi GS, dos Reis AC, Valente MLdC. Influence of fabrication material and manufacturing technique on the internal adaptation of post-and-cores: a systematic review. J Prosthet Dent. 2025;134(6):2102.e1–e14. DOI: https://doi.org/10.1016/j.prosdent.2025.08.016

Bassiouny D, Petersmann S, Zohdy M, Morsi T, Taha D. Trueness and intaglio fit of custom-made polyetheretherketone post-and-cores fabricated using different techniques. J Prosthet Dent. 2025;133(3):811–9. DOI: https://doi.org/10.1016/j.prosdent.2024.06.026

Gama M, Balbinot G, Ferreira G, Mota E, Leitune V, Collares F. CAD/CAM milled glass fiber posts: adaptation and mechanical behavior in flared root canals. Oper Dent. 2021;46(4):438–47. DOI: https://doi.org/10.2341/20-198-L

Prachasujit W, Urapepon S. Development of fibre-reinforced composite disk for computer-aided design-computer-aided manufacturing milled posts; Experimental composite disk using e-glass fibre in different fibre direction. J Indian Prosthodont Soc. 2021;21(4):425–9. DOI: https://doi.org/10.4103/jips.jips_135_21

dos Santos SJ, Felizardo K, Guiraldo R, Berger S, Lopes M. Flexural Strength and Stress Analysis of CAD-CAM Milled Glass Fiber Post and Core. Int J Dent. 2025;2025:6298753. DOI: https://doi.org/10.1155/ijod/6298753

Page MJ, McKenzie JE, Bossuyt PM, Boutron I, Hoffmann TC, Mulrow CD, et al. The PRISMA 2020 statement: an updated guideline for reporting systematic reviews. Int J Surg Lond Engl. 2021;88:105906. DOI: https://doi.org/10.1016/j.ijsu.2021.105906

Faggion CMJ. Guidelines for reporting pre-clinical in vitro studies on dental materials. J Evid-Based Dent Pract. 2012;12(4):182–9. DOI: https://doi.org/10.1016/j.jebdp.2012.10.001

Fathey IT, Azer AS, Abdelraheem IM. Fracture resistance and failure mode of three esthetic CAD-CAM post and core restorations. BMC Oral Health. 2024;24(1):523. DOI: https://doi.org/10.1186/s12903-024-04273-y

Ghanem NA, Baherly NA, Hassan HS. Fracture resistance of custom-milled CAD/CAM post and core using two different materials: an in vitro study. J Stomatol. 2022;75(4):207–15. DOI: https://doi.org/10.5114/jos.2022.122083

Jrab B, Saleh A, Al-Jadaa A, Jurado C, Saeed M, Afrashtehfar K. Fracture resistance of CAD/CAM tooth-colored versus cast metal post-and-core restorations in root filled teeth: an in vitro study. SAUDI Dent J. 2024;36(9):1215–20. DOI: https://doi.org/10.1016/j.sdentj.2024.07.002

Gontijo IG, Ferretti MA, Caldas RA, Pecorari VGA, França FMG, Oliveira LKN, et al. Biomechanical behavior of weakened roots restored with custom-made post-and-cores of glass fiber and polyetheretherketone. J Prosthodont. 2023;32(9):807–14. DOI: https://doi.org/10.1111/jopr.13628

Altitinchi A, Hussein A, Saemundsson S, Clark W, Culp L, Sulaiman T. Anatomic CAD-CAM post-and-core systems: a mastication simulation study. J Prosthet Dent. 2024;132(3):586–91. DOI: https://doi.org/10.1016/j.prosdent.2022.08.017

Pelegrine R, Kato A, Seckler I, Bueno C, Pinheiro S, Lima D, et al. Impact of mechanical load of three post and core systems: CAD/CAM-fabricated glassfiber, prefabricated glassfiber customized with composite resin, and cast metal posts and cores. Conserv Dent Endod J. 2021;5:36–41. DOI: https://doi.org/10.5005/jp-journals-10048-0064

Ruschel GH, Gomes ÉA, Silva-Sousa YT, Pinelli RGP, Sousa-Neto MD, Pereira GKR, et al. Mechanical properties and superficial characterization of a milled CAD-CAM glass fiber post. J Mech Behav Biomed Mater. 2018;82:187–92. DOI: https://doi.org/10.1016/j.jmbbm.2018.03.035

Ibrahim BH, Beleidy ME, Hamdy AM, Sadek HMA. The effect of different materials and lengths of custom made post and core on the fracture resistance of endodontically treated teeth. Ain Shams Dent J Egypt. 2025;37(1):132–40. DOI: https://doi.org/10.21608/asdj.2024.331181.1601

Hamitoglu B, Ozkurt-Kayahan Z. Fracture resistance of endodontically treated teeth restored with CAD-CAM milled and prefabricated post-and-core systems. J Prosthodont. 2025;34(3):664-670. DOI: https://doi.org/10.1111/jopr.14023

Alessi RS, Gomes GM, Gomes JC. Fracture resistance of teeth restored with anatomic, universal 2-piece, and CAD/CAM milled glass fiber posts in various weakened root conditions. J Clin Exp Dent. 2025;17(10):e1220–9. DOI: https://doi.org/10.4317/jced.63165

Dietschi D, Duc O, Krejci I, Sadan A. Biomechanical considerations for the restoration of endodontically treated teeth: a systematic review of the literature, Part II (Evaluation of fatigue behavior, interfaces, and in vivo studies). Quintessence Int. 2008;39(2):117–29.

Grandini S, Balleri P, Ferrari M. Scanning electron microscopic investigation of the surface of fiber posts after cutting. J Endod. 2002;28(8): 610–2. DOI: https://doi.org/10.1097/00004770-200208000-00012

Additional Files

Published

2026-08-19

How to Cite

Yousfi, A., & Dakhli, R. (2026). Fracture strength of CAD/CAM glass fiber post-and-cores: a systematic review. Biomaterial Investigations in Dentistry, 13(1), 674–684. https://doi.org/10.2340/biid.v13.46724